 "id": "radiography-safety",
 "modality": "Radiography",
 "category": "Safety",
 "title": "Radiography Safety: Physics, Dose and Protection",
 "minutes": 9,
 "slides": [
  {
   "id": 1,
   "diagram": "title",
   "heading": "Radiography Safety",
   "bullets": [
    "50 of 200 scored questions (25%)",
    "Physics, radiobiology, units, patient and staff protection"
   ],
   "narration": "Welcome to Radiography Safety. This is the second biggest section on the radiography boards, 50 of the 200 scored questions, a full 25 percent. We'll cover how x-rays are made and interact, the inverse square law, dose units, radiobiology, and how you protect your patients and yourself, including fluoroscopy limits and dose limits. There are lots of numbers here, and the boards love to test them, so let's take them one at a time.",
   "svg": "<svg xmlns=\"http://www.w3.org/2000/svg\" viewBox=\"0 0 320 200\" role=\"img\" aria-label=\"Title card: Safety is 50 of 200 scored radiography questions, 25 percent, shown as a pie wedge.\" font-family=\"inherit\"><text x=\"16\" y=\"70\" font-size=\"14\" fill=\"currentColor\">Radiography</text><text x=\"16\" y=\"98\" font-size=\"22\" font-weight=\"700\" fill=\"currentColor\">Safety</text><text x=\"16\" y=\"128\" font-size=\"16\" style=\"fill:var(--ib-pink)\">50 of 200</text><text x=\"16\" y=\"150\" font-size=\"12\" fill=\"currentColor\">25% of scored items</text><circle cx=\"250\" cy=\"100\" r=\"50\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"/><path d=\"M250 100 L250 50 A50 50 0 0 1 300.0 100.0 Z\" style=\"fill:var(--ib-pink)\"/></svg>"
  },
  {
   "id": 2,
   "diagram": "xray-tube",
   "heading": "How x-rays are made",
   "bullets": [
    "Thermionic emission at the tungsten filament",
    "Over 99% heat, under 1% x-rays",
    "Bremsstrahlung makes most of the beam",
    "Max photon energy (keV) = kVp",
    "Tungsten: Z 74, K-shell 69.5 keV"
   ],
   "narration": "Electrons boil off the heated tungsten filament by thermionic emission, get focused by the focusing cup, and are accelerated by the k V p into the anode target. Over 99 percent of that energy becomes heat, and under 1 percent becomes x-rays. Bremsstrahlung, or braking radiation, makes most of the beam. The maximum photon energy in k e V equals the k V p, not the m A. Tungsten has an atomic number of 74 and a K-shell binding energy of 69.5 k e V.",
   "svg": "<svg xmlns=\"http://www.w3.org/2000/svg\" viewBox=\"0 0 320 200\" role=\"img\" aria-label=\"X-ray tube schematic: electrons leave the cathode filament, strike the angled tungsten anode, and x-rays exit downward; over 99 percent becomes heat.\" font-family=\"inherit\"><text x=\"160\" y=\"22\" font-size=\"13\" text-anchor=\"middle\" style=\"fill:var(--ib-pink)\">Over 99% heat</text><rect x=\"30\" y=\"40\" width=\"260\" height=\"70\" rx=\"30\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"/><path d=\"M58 58 L58 92 L78 92 L78 84 L66 84 L66 66 L78 66 L78 58 Z\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"/><path d=\"M70 70 l3 -4 l3 8 l3 -8 l3 8 l3 -4\" fill=\"none\" style=\"stroke:var(--ib-pink)\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"/><line x1=\"90\" y1=\"75\" x2=\"210\" y2=\"75\" style=\"stroke:var(--ib-pink)\" stroke-width=\"2\"/><path d=\"M220.0 75.0 L213.0 71.5 L213.0 78.5 Z\" style=\"fill:var(--ib-pink)\"/><text x=\"150\" y=\"68\" font-size=\"12\" text-anchor=\"middle\" fill=\"currentColor\">e-</text><path d=\"M226 56 L250 56 L250 98 L238 98 Z\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"/><line x1=\"250\" y1=\"75\" x2=\"278\" y2=\"75\" stroke=\"currentColor\" stroke-width=\"2\"/><line x1=\"232\" y1=\"82\" x2=\"200\" y2=\"170\" stroke=\"currentColor\" stroke-width=\"2\" stroke-dasharray=\"4 3\"/><line x1=\"232\" y1=\"82\" x2=\"264\" y2=\"170\" stroke=\"currentColor\" stroke-width=\"2\" stroke-dasharray=\"4 3\"/><text x=\"194\" y=\"160\" font-size=\"12\" text-anchor=\"end\" fill=\"currentColor\">X-rays</text><text x=\"16\" y=\"132\" font-size=\"12\" fill=\"currentColor\">Cathode (-)</text><text x=\"16\" y=\"150\" font-size=\"12\" fill=\"currentColor\">tungsten filament</text><text x=\"304\" y=\"28\" font-size=\"12\" text-anchor=\"end\" fill=\"currentColor\">Anode (+)</text><text x=\"16\" y=\"186\" font-size=\"13\" font-weight=\"700\" style=\"fill:var(--ib-pink)\">Max keV = kVp</text></svg>"
  },
  {
   "id": 3,
   "diagram": "interactions",
   "heading": "Photon interactions",
   "bullets": [
    "Photoelectric: inner shell, photon absorbed",
    "Photoelectric rises with Z cubed, low kVp",
    "Compton: outer shell, fog and staff dose",
    "Coherent: below 10 keV, no ionization"
   ],
   "narration": "Photoelectric absorption hits an inner shell electron, and the photon is totally absorbed. That creates contrast and most patient dose. Its probability rises with atomic number cubed and falls with energy, so it dominates at low k V p. Compton scatter hits an outer shell electron and the photon scatters with less energy. It causes image fog and most occupational exposure. Coherent scatter happens below about 10 k e V, with no ionization. Pair production never happens in diagnostic radiography.",
   "svg": "<svg xmlns=\"http://www.w3.org/2000/svg\" viewBox=\"0 0 320 200\" role=\"img\" aria-label=\"Two atoms: photoelectric absorption where a photon is absorbed by an inner-shell electron, and Compton scatter where a photon hits an outer-shell electron and scatters.\" font-family=\"inherit\"><text x=\"80\" y=\"24\" font-size=\"13\" text-anchor=\"middle\" font-weight=\"700\" fill=\"currentColor\">Photoelectric</text><text x=\"240\" y=\"24\" font-size=\"13\" text-anchor=\"middle\" font-weight=\"700\" fill=\"currentColor\">Compton</text><circle cx=\"90\" cy=\"100\" r=\"6\" fill=\"currentColor\"/><circle cx=\"90\" cy=\"100\" r=\"20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.5\"/><circle cx=\"90\" cy=\"100\" r=\"38\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.5\"/><path d=\"M16 70 L20 76 L26 74 L32 72 L36 78 L40 84 L46 82 L52 80 L56 86 L60 92 L66 90 L72 88 L76 94\" fill=\"none\" style=\"stroke:var(--ib-pink)\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"/><circle cx=\"90\" cy=\"80\" r=\"4\" style=\"fill:var(--ib-pink)\"/><line x1=\"90\" y1=\"80\" x2=\"128\" y2=\"56\" stroke=\"currentColor\" stroke-width=\"2\"/><path d=\"M132.0 53.0 L125.4 54.0 L128.8 58.9 Z\" fill=\"currentColor\"/><text x=\"80\" y=\"166\" font-size=\"12\" text-anchor=\"middle\" fill=\"currentColor\">Inner shell</text><text x=\"80\" y=\"184\" font-size=\"12\" text-anchor=\"middle\" style=\"fill:var(--ib-pink)\">Photon absorbed</text><circle cx=\"240\" cy=\"100\" r=\"6\" fill=\"currentColor\"/><circle cx=\"240\" cy=\"100\" r=\"20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.5\"/><circle cx=\"240\" cy=\"100\" r=\"38\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.5\"/><path d=\"M170 52 L173 57 L178 54 L184 52 L187 57 L190 62 L195 59 L200 56 L203 61 L206 66 L212 64 L217 61 L220 66\" fill=\"none\" style=\"stroke:var(--ib-pink)\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"/><circle cx=\"226\" cy=\"66\" r=\"4\" style=\"fill:var(--ib-pink)\"/><line x1=\"228\" y1=\"62\" x2=\"262\" y2=\"46\" stroke=\"currentColor\" stroke-width=\"2\"/><path d=\"M266.0 44.0 L259.3 44.2 L262.1 49.5 Z\" fill=\"currentColor\"/><path d=\"M228 70 L231 77 L238 78 L246 79 L249 87 L251 94 L259 95 L267 96 L269 103 L272 111 L280 112 L287 113 L290 120\" fill=\"none\" style=\"stroke:var(--ib-pink)\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"/><text x=\"240\" y=\"166\" font-size=\"12\" text-anchor=\"middle\" fill=\"currentColor\">Outer shell</text><text x=\"240\" y=\"184\" font-size=\"12\" text-anchor=\"middle\" style=\"fill:var(--ib-pink)\">Photon scatters</text></svg>"
  },
  {
   "id": 4,
   "diagram": "inverse-square",
   "heading": "Beam and inverse square",
   "bullets": [
    "Quality: kVp and filtration, measured by HVL",
    "Quantity is directly proportional to mAs",
    "Double the distance = one quarter intensity",
    "Double SID = four times the mAs",
    "+15% kVp roughly doubles receptor exposure"
   ],
   "narration": "Beam quality, or penetrability, is controlled by k V p and filtration and measured by half value layer. Beam quantity is directly proportional to m A s. The inverse square law says intensity varies with one over distance squared, so double the distance and you get one quarter the intensity. The exposure maintenance formula goes the other way: double the source to image distance and you need four times the m A s. And the 15 percent rule: raising k V p 15 percent roughly doubles receptor exposure.",
   "svg": "<svg xmlns=\"http://www.w3.org/2000/svg\" viewBox=\"0 0 320 200\" role=\"img\" aria-label=\"Inverse square law: x-rays from a point spread so that doubling distance from d to 2d spreads the beam over four times the area, giving one quarter the intensity.\" font-family=\"inherit\"><circle cx=\"28\" cy=\"96\" r=\"4\" fill=\"currentColor\"/><line x1=\"28\" y1=\"96\" x2=\"228\" y2=\"56\" style=\"stroke:var(--stroke-primary)\" stroke-width=\"1\"/><line x1=\"28\" y1=\"96\" x2=\"228\" y2=\"136\" style=\"stroke:var(--stroke-primary)\" stroke-width=\"1\"/><rect x=\"124\" y=\"76\" width=\"4\" height=\"40\" rx=\"0\" style=\"fill:var(--ib-pink)\"/><rect x=\"224\" y=\"56\" width=\"4\" height=\"80\" rx=\"0\" fill=\"none\" style=\"stroke:var(--ib-pink)\" stroke-width=\"2\"/><text x=\"126\" y=\"68\" font-size=\"13\" text-anchor=\"middle\" font-weight=\"700\" fill=\"currentColor\">I</text><text x=\"226\" y=\"48\" font-size=\"13\" text-anchor=\"middle\" font-weight=\"700\" style=\"fill:var(--ib-pink)\">I / 4</text><line x1=\"28\" y1=\"150\" x2=\"126\" y2=\"150\" stroke=\"currentColor\" stroke-width=\"1\"/><text x=\"77\" y=\"166\" font-size=\"13\" text-anchor=\"middle\" fill=\"currentColor\">d</text><line x1=\"126\" y1=\"146\" x2=\"126\" y2=\"154\" stroke=\"currentColor\" stroke-width=\"1\"/><line x1=\"28\" y1=\"146\" x2=\"28\" y2=\"154\" stroke=\"currentColor\" stroke-width=\"1\"/><line x1=\"126\" y1=\"150\" x2=\"226\" y2=\"150\" stroke=\"currentColor\" stroke-width=\"1\"/><line x1=\"226\" y1=\"146\" x2=\"226\" y2=\"154\" stroke=\"currentColor\" stroke-width=\"1\"/><text x=\"176\" y=\"166\" font-size=\"12\" text-anchor=\"middle\" fill=\"currentColor\">2d total</text><text x=\"16\" y=\"190\" font-size=\"13\" fill=\"currentColor\">I1 / I2 = (D2 / D1)²</text><text x=\"304\" y=\"190\" font-size=\"12\" text-anchor=\"end\" style=\"fill:var(--ib-pink)\">2x SID: 4x mAs</text><text x=\"16\" y=\"24\" font-size=\"12\" fill=\"currentColor\">Same photons, 4x area</text></svg>"
  },
  {
   "id": 5,
   "diagram": "si-units",
   "heading": "SI units",
   "bullets": [
    "Exposure: coulombs per kilogram (C/kg)",
    "Absorbed dose: gray; 1 Gy = 100 rad",
    "Equivalent dose: sievert; 1 Sv = 100 rem",
    "Weighting factor: x-rays 1, alpha 20",
    "Effective dose adds tissue weighting factors"
   ],
   "narration": "SI units are what the boards use. Exposure is measured in coulombs per kilogram of air, and air kerma, in gray, has largely replaced it. Absorbed dose is in gray, and one gray equals 100 rad. Equivalent dose is in sievert, and one sievert equals 100 rem. The radiation weighting factor is 1 for x-rays and 20 for alpha particles, so for x-rays a gray equals a sievert. Effective dose adds tissue weighting factors to estimate whole body risk.",
   "svg": "<svg xmlns=\"http://www.w3.org/2000/svg\" viewBox=\"0 0 320 200\" role=\"img\" aria-label=\"SI units table: exposure in coulombs per kilogram, absorbed dose in gray equal to 100 rad, equivalent and effective dose in sievert equal to 100 rem, with radiation weighting factors.\" font-family=\"inherit\"><text x=\"16\" y=\"30\" font-size=\"13\" font-weight=\"700\" fill=\"currentColor\">Quantity</text><text x=\"150\" y=\"30\" font-size=\"13\" font-weight=\"700\" fill=\"currentColor\">SI</text><text x=\"230\" y=\"30\" font-size=\"13\" font-weight=\"700\" fill=\"currentColor\">Old</text><line x1=\"16\" y1=\"39\" x2=\"304\" y2=\"39\" style=\"stroke:var(--stroke-primary)\" stroke-width=\"1\"/><text x=\"16\" y=\"58\" font-size=\"13\" fill=\"currentColor\">Exposure</text><text x=\"150\" y=\"58\" font-size=\"13\" font-weight=\"700\" style=\"fill:var(--ib-pink)\">C/kg</text><text x=\"230\" y=\"58\" font-size=\"13\" fill=\"currentColor\">R</text><line x1=\"16\" y1=\"67\" x2=\"304\" y2=\"67\" style=\"stroke:var(--stroke-primary)\" stroke-width=\"1\"/><text x=\"16\" y=\"86\" font-size=\"13\" fill=\"currentColor\">Absorbed</text><text x=\"150\" y=\"86\" font-size=\"13\" font-weight=\"700\" style=\"fill:var(--ib-pink)\">Gy</text><text x=\"230\" y=\"86\" font-size=\"13\" fill=\"currentColor\">100 rad</text><line x1=\"16\" y1=\"95\" x2=\"304\" y2=\"95\" style=\"stroke:var(--stroke-primary)\" stroke-width=\"1\"/><text x=\"16\" y=\"114\" font-size=\"13\" fill=\"currentColor\">Equivalent</text><text x=\"150\" y=\"114\" font-size=\"13\" font-weight=\"700\" style=\"fill:var(--ib-pink)\">Sv</text><text x=\"230\" y=\"114\" font-size=\"13\" fill=\"currentColor\">100 rem</text><line x1=\"16\" y1=\"123\" x2=\"304\" y2=\"123\" style=\"stroke:var(--stroke-primary)\" stroke-width=\"1\"/><text x=\"16\" y=\"142\" font-size=\"13\" fill=\"currentColor\">Effective</text><text x=\"150\" y=\"142\" font-size=\"13\" font-weight=\"700\" style=\"fill:var(--ib-pink)\">Sv</text><text x=\"230\" y=\"142\" font-size=\"13\" fill=\"currentColor\">risk</text><line x1=\"16\" y1=\"151\" x2=\"304\" y2=\"151\" style=\"stroke:var(--stroke-primary)\" stroke-width=\"1\"/><text x=\"16\" y=\"178\" font-size=\"13\" style=\"fill:var(--ib-pink)\">WR: x-ray 1, alpha 20</text></svg>"
  },
  {
   "id": 6,
   "diagram": "radiosensitivity",
   "heading": "Radiobiology",
   "bullets": [
    "Bergonie and Tribondeau: immature, dividing cells",
    "Lymphocytes most sensitive; nerve, muscle least",
    "Most damage is indirect, via free radicals",
    "Stochastic: no threshold (cancer, genetic)",
    "Deterministic: threshold (erythema, cataract)"
   ],
   "narration": "The law of Bergonie and Tribondeau says cells are most radiosensitive when they are immature, undifferentiated and rapidly dividing. Lymphocytes are the most sensitive blood cells, while nerve and muscle cells are the least. Most x-ray damage is indirect, through radiolysis of water making free radicals that hit DNA. Stochastic effects, like cancer and genetic effects, have no threshold. Deterministic effects, like skin erythema around 2 gray and cataracts, have a threshold, and severity rises with dose.",
   "svg": "<svg xmlns=\"http://www.w3.org/2000/svg\" viewBox=\"0 0 320 200\" role=\"img\" aria-label=\"Dose-response graph: a straight linear non-threshold line for stochastic effects and an S-shaped threshold curve for deterministic effects.\" font-family=\"inherit\"><line x1=\"40\" y1=\"168\" x2=\"300\" y2=\"168\" stroke=\"currentColor\" stroke-width=\"2\"/><line x1=\"40\" y1=\"168\" x2=\"40\" y2=\"20\" stroke=\"currentColor\" stroke-width=\"2\"/><path d=\"M304.0 168.0 L298.0 165.0 L298.0 171.0 Z\" fill=\"currentColor\"/><path d=\"M40.0 16.0 L37.0 22.0 L43.0 22.0 Z\" fill=\"currentColor\"/><text x=\"296\" y=\"188\" font-size=\"12\" text-anchor=\"end\" fill=\"currentColor\">Dose</text><text x=\"48\" y=\"28\" font-size=\"12\" fill=\"currentColor\">Effect</text><line x1=\"40\" y1=\"168\" x2=\"260\" y2=\"40\" style=\"stroke:var(--ib-pink)\" stroke-width=\"2\"/><path d=\"M40 168 L150 168 C190 168 200 60 290 52\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"/><line x1=\"150\" y1=\"168\" x2=\"150\" y2=\"176\" stroke=\"currentColor\" stroke-width=\"1\"/><text x=\"150\" y=\"190\" font-size=\"12\" text-anchor=\"middle\" fill=\"currentColor\">Threshold</text><text x=\"128\" y=\"92\" font-size=\"12\" text-anchor=\"end\" style=\"fill:var(--ib-pink)\">Stochastic</text><text x=\"128\" y=\"108\" font-size=\"12\" text-anchor=\"end\" style=\"fill:var(--ib-pink)\">no threshold</text><text x=\"214\" y=\"128\" font-size=\"12\" fill=\"currentColor\">Deterministic</text><text x=\"214\" y=\"144\" font-size=\"12\" fill=\"currentColor\">threshold</text></svg>"
  },
  {
   "id": 7,
   "diagram": "collimation",
   "heading": "Reducing patient dose",
   "bullets": [
    "Highest practical kVp, lowest mAs",
    "Collimate; light field within 2% of SID",
    "Total filtration 2.5 mm Al above 70 kVp",
    "PA instead of AP spares breast, thyroid, eyes",
    "Electronic cropping does not reduce dose"
   ],
   "narration": "To cut patient dose, use the highest practical k V p with the lowest m A s. Collimate to the area of interest, and know that the light field must line up with the x-ray field within 2 percent of the source to image distance. Total filtration must be at least 2.5 millimeters of aluminum equivalent above 70 k V p. Use P A instead of A P when you can, to spare the breasts, thyroid and eyes. And electronic cropping after the exposure does not reduce dose. Only collimation does.",
   "svg": "<svg xmlns=\"http://www.w3.org/2000/svg\" viewBox=\"0 0 320 200\" role=\"img\" aria-label=\"Beam restriction: tube, filter and collimator above the patient; tight collimation narrows the field compared with an open field.\" font-family=\"inherit\"><rect x=\"124\" y=\"12\" width=\"72\" height=\"22\" rx=\"4\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"/><text x=\"160\" y=\"28\" font-size=\"12\" text-anchor=\"middle\" fill=\"currentColor\">Tube</text><line x1=\"132\" y1=\"38\" x2=\"188\" y2=\"38\" style=\"stroke:var(--ib-pink)\" stroke-width=\"3\"/><rect x=\"136\" y=\"42\" width=\"48\" height=\"16\" rx=\"4\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"/><line x1=\"160\" y1=\"58\" x2=\"96\" y2=\"150\" style=\"stroke:var(--stroke-primary)\" stroke-width=\"1\" stroke-dasharray=\"4 3\"/><line x1=\"160\" y1=\"58\" x2=\"224\" y2=\"150\" style=\"stroke:var(--stroke-primary)\" stroke-width=\"1\" stroke-dasharray=\"4 3\"/><line x1=\"160\" y1=\"58\" x2=\"134\" y2=\"150\" style=\"stroke:var(--ib-pink)\" stroke-width=\"2\"/><line x1=\"160\" y1=\"58\" x2=\"186\" y2=\"150\" style=\"stroke:var(--ib-pink)\" stroke-width=\"2\"/><path d=\"M80 160 Q160 140 240 160 Q160 182 80 160 Z\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"/><text x=\"16\" y=\"42\" font-size=\"12\" fill=\"currentColor\">Filter</text><text x=\"16\" y=\"58\" font-size=\"12\" style=\"fill:var(--ib-pink)\">2.5 mm Al</text><text x=\"304\" y=\"54\" font-size=\"12\" text-anchor=\"end\" fill=\"currentColor\">Collimator</text><text x=\"16\" y=\"110\" font-size=\"12\" fill=\"currentColor\">Open field</text><text x=\"304\" y=\"110\" font-size=\"12\" text-anchor=\"end\" style=\"fill:var(--ib-pink)\">Collimated</text><text x=\"16\" y=\"192\" font-size=\"12\" fill=\"currentColor\">Light field within 2% SID</text></svg>"
  },
  {
   "id": 8,
   "diagram": "fluoro",
   "heading": "Fluoroscopy limits",
   "bullets": [
    "Normal mode max 88 mGy/min (10 R/min)",
    "High-level max 176 mGy/min (20 R/min)",
    "SSD at least 38 cm fixed, 30 cm mobile",
    "5-minute timer alerts; it does not stop the beam",
    "Receptor close, tube far; magnification adds dose"
   ],
   "narration": "Fluoroscopy limits are tested constantly. In normal mode, tabletop air kerma rate is capped at 88 milligrays per minute, which is 10 roentgens per minute. High level control is capped at 176 milligrays per minute, or 20. Source to skin distance must be at least 38 centimeters on fixed units and 30 on mobile C-arms. The 5 minute timer only alerts you, it does not stop the beam. Keep the receptor close and the tube far, and remember magnification mode raises patient dose.",
   "svg": "<svg xmlns=\"http://www.w3.org/2000/svg\" viewBox=\"0 0 320 200\" role=\"img\" aria-label=\"Under-table fluoroscopy: x-ray tube below the table, patient on the table, image receptor close above; source-to-skin distance at least 38 centimeters.\" font-family=\"inherit\"><rect x=\"112\" y=\"16\" width=\"96\" height=\"18\" rx=\"4\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"/><text x=\"160\" y=\"30\" font-size=\"12\" text-anchor=\"middle\" fill=\"currentColor\">Receptor</text><line x1=\"160\" y1=\"162\" x2=\"116\" y2=\"34\" style=\"stroke:var(--ib-pink)\" stroke-width=\"1.5\"/><line x1=\"160\" y1=\"162\" x2=\"204\" y2=\"34\" style=\"stroke:var(--ib-pink)\" stroke-width=\"1.5\"/><path d=\"M104 92 Q160 66 216 92 Q160 112 104 92 Z\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"/><line x1=\"80\" y1=\"108\" x2=\"260\" y2=\"108\" stroke=\"currentColor\" stroke-width=\"2\"/><rect x=\"140\" y=\"162\" width=\"40\" height=\"18\" rx=\"4\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"/><text x=\"190\" y=\"176\" font-size=\"12\" fill=\"currentColor\">Tube</text><line x1=\"98\" y1=\"102\" x2=\"98\" y2=\"162\" stroke=\"currentColor\" stroke-width=\"1\"/><path d=\"M98.0 102.0 L95.5 107.0 L100.5 107.0 Z\" fill=\"currentColor\"/><path d=\"M98.0 162.0 L100.5 157.0 L95.5 157.0 Z\" fill=\"currentColor\"/><text x=\"90\" y=\"128\" font-size=\"12\" text-anchor=\"end\" fill=\"currentColor\">SSD</text><text x=\"90\" y=\"144\" font-size=\"12\" text-anchor=\"end\" style=\"fill:var(--ib-pink)\">38 cm+</text><text x=\"224\" y=\"30\" font-size=\"12\" style=\"fill:var(--ib-pink)\">Close</text><text x=\"16\" y=\"30\" font-size=\"12\" fill=\"currentColor\">Max</text><text x=\"16\" y=\"46\" font-size=\"12\" style=\"fill:var(--ib-pink)\">88 mGy/min</text><text x=\"304\" y=\"140\" font-size=\"12\" text-anchor=\"end\" fill=\"currentColor\">Timer</text><text x=\"304\" y=\"156\" font-size=\"12\" text-anchor=\"end\" style=\"fill:var(--ib-pink)\">5 min</text></svg>"
  },
  {
   "id": 9,
   "diagram": "dose-limits",
   "heading": "Staff protection and limits",
   "bullets": [
    "Time, distance, shielding; distance is best",
    "Aprons at least 0.25 mm Pb equivalent",
    "Occupational 50 mSv/yr; cumulative 10 x age",
    "Lens 150 mSv/yr; skin, extremities 500 mSv/yr",
    "Public 1 mSv/yr; fetus 0.5 mSv per month"
   ],
   "narration": "Protect yourself with time, distance and shielding, and distance is the most effective. Protective aprons must be at least 0.25 millimeters of lead equivalent. Under N C R P report 116, the occupational effective dose limit is 50 millisieverts per year, with a cumulative limit of 10 millisieverts times your age. The lens limit is 150 millisieverts per year, and skin and extremities 500. The public limit is 1 millisievert per year, and the embryo of a declared pregnant worker is limited to 0.5 millisieverts per month.",
   "svg": "<svg xmlns=\"http://www.w3.org/2000/svg\" viewBox=\"0 0 320 200\" role=\"img\" aria-label=\"Staff protection icons for time, distance and shielding, with occupational and fetal dose limits.\" font-family=\"inherit\"><circle cx=\"56\" cy=\"52\" r=\"26\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"/><line x1=\"56\" y1=\"52\" x2=\"56\" y2=\"34\" stroke=\"currentColor\" stroke-width=\"2\"/><line x1=\"56\" y1=\"52\" x2=\"70\" y2=\"58\" stroke=\"currentColor\" stroke-width=\"2\"/><line x1=\"124\" y1=\"52\" x2=\"196\" y2=\"52\" stroke=\"currentColor\" stroke-width=\"2\"/><path d=\"M200.0 52.0 L193.0 48.5 L193.0 55.5 Z\" fill=\"currentColor\"/><path d=\"M120.0 52.0 L127.0 55.5 L127.0 48.5 Z\" fill=\"currentColor\"/><path d=\"M264 28 L286 36 L286 56 Q286 72 264 80 Q242 72 242 56 L242 36 Z\" fill=\"none\" style=\"stroke:var(--ib-pink)\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"/><text x=\"56\" y=\"100\" font-size=\"12\" text-anchor=\"middle\" fill=\"currentColor\">Time</text><text x=\"160\" y=\"100\" font-size=\"12\" text-anchor=\"middle\" font-weight=\"700\" style=\"fill:var(--ib-pink)\">Distance</text><text x=\"264\" y=\"100\" font-size=\"12\" text-anchor=\"middle\" fill=\"currentColor\">Shielding</text><line x1=\"16\" y1=\"114\" x2=\"304\" y2=\"114\" style=\"stroke:var(--stroke-primary)\" stroke-width=\"1\"/><text x=\"16\" y=\"138\" font-size=\"12\" fill=\"currentColor\">Occupational</text><text x=\"304\" y=\"138\" font-size=\"12\" text-anchor=\"end\" style=\"fill:var(--ib-pink)\">50 mSv/yr</text><text x=\"16\" y=\"162\" font-size=\"12\" fill=\"currentColor\">Cumulative</text><text x=\"304\" y=\"162\" font-size=\"12\" text-anchor=\"end\" fill=\"currentColor\">10 mSv x age</text><text x=\"16\" y=\"186\" font-size=\"12\" fill=\"currentColor\">Fetus (declared)</text><text x=\"304\" y=\"186\" font-size=\"12\" text-anchor=\"end\" style=\"fill:var(--ib-pink)\">0.5 mSv/month</text></svg>"
  },
  {
   "id": 10,
   "diagram": "summary",
   "heading": "Lock these in",
   "bullets": [
    "Max keV = kVp",
    "Double distance = 1/4 intensity",
    "Lymphocytes: most radiosensitive blood cells",
    "Occupational 50 mSv/yr; fetus 0.5 mSv/month",
    "Fluoro normal max 88 mGy/min (10 R/min)"
   ],
   "narration": "Let's lock it in. Maximum k e V equals k V p. Double the distance, and you get one quarter the intensity. Lymphocytes are the most radiosensitive blood cells. The occupational limit is 50 millisieverts per year, and a declared pregnancy limits the fetus to 0.5 millisieverts per month. And the normal mode fluoroscopy maximum is 88 milligrays per minute, or 10 roentgens per minute. Now hit Practice this chapter and test yourself.",
   "svg": "<svg xmlns=\"http://www.w3.org/2000/svg\" viewBox=\"0 0 320 200\" role=\"img\" aria-label=\"Summary checklist of five safety facts.\" font-family=\"inherit\"><rect x=\"16\" y=\"22\" width=\"18\" height=\"18\" rx=\"3\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"/><path d=\"M19 30 l4 4 l8 -9\" fill=\"none\" style=\"stroke:var(--ib-pink)\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"/><text x=\"46\" y=\"36\" font-size=\"13\" fill=\"currentColor\">Max keV = kVp</text><rect x=\"16\" y=\"56\" width=\"18\" height=\"18\" rx=\"3\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"/><path d=\"M19 64 l4 4 l8 -9\" fill=\"none\" style=\"stroke:var(--ib-pink)\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"/><text x=\"46\" y=\"70\" font-size=\"13\" fill=\"currentColor\">Double distance: 1/4</text><rect x=\"16\" y=\"90\" width=\"18\" height=\"18\" rx=\"3\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"/><path d=\"M19 98 l4 4 l8 -9\" fill=\"none\" style=\"stroke:var(--ib-pink)\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"/><text x=\"46\" y=\"104\" font-size=\"13\" fill=\"currentColor\">Lymphocytes most sensitive</text><rect x=\"16\" y=\"124\" width=\"18\" height=\"18\" rx=\"3\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"/><path d=\"M19 132 l4 4 l8 -9\" fill=\"none\" style=\"stroke:var(--ib-pink)\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"/><text x=\"46\" y=\"138\" font-size=\"13\" fill=\"currentColor\">50 mSv/yr; fetus 0.5/mo</text><rect x=\"16\" y=\"158\" width=\"18\" height=\"18\" rx=\"3\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"/><path d=\"M19 166 l4 4 l8 -9\" fill=\"none\" style=\"stroke:var(--ib-pink)\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"/><text x=\"46\" y=\"172\" font-size=\"13\" fill=\"currentColor\">Fluoro max 88 mGy/min</text></svg>"
  }
 ]
}